Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Features | Description | |
Input | Input AC voltage | 1AC 220V±15%,3AC 220V±15%,3AC 380V±15% |
Recommend pv input DC voltage range | 160~380VDC; 350~750VDC(Maximum input DC voltage:800VDC) | |
Input frequency range | 47~63Hz | |
Power factor | ≥97% | |
Control performance | Control mode | V/F control,non-PG vector control(SVC),PG vector control(FVC) |
V/F control | Linear,multipoint,spuare V/F curve,V/F seperation | |
Operation command mode | Keypad control,Terminal control,Serial communication control | |
Frequency Reference Source | Digital,analog,pulse frequency,serial communication,multi-step speed,simple PLC and PID The combinaton of multi-modes and the different modes can be switched. | |
Overload capacity | 150%rated current 60s,180%rated current 3s | |
Start torque | G type:0.5Hz/150%(SVC),OHz/180%(FVC) | |
Speed adjusting range | 1:100(SVC) ; 1:1000(FVC) | |
Speed control accuracy | ±0.5%(SVC); ±0.02%(FVC) | |
Automatic voltage regulation(AVR) | Automatically maintain a constant output voltage when the voltage of electricity grid changes | |
Protection function | Overvolatge protection,undervoltage protection,overcurrent proteciton,overload protection,overheat protection,overcurrent stall protection,overvoltage stall protection,phase-loss protection,over-speed detection,motor overheat protection,short-circuit protection. | |
The specific function of solar pump inveter | CVT or MPPT control mode,maximum power point tracking,light weak auto sleep,light strong auto wake up,pre-warning at weak light,underload pre-warning,pre-warning when full water,fault protection of water level sensor,low water level automatic run,etc. | |
Terminals | Input terminals | 6 programmable digital inputs,it can be extended to 4 digital inputs,one of which supports high speed pulse input; 1 analog volatge input 0~10VDC; 2 volatge input 0~10VDC or current input 0~20mA |
Output terminals | 1 open collector output ,it can be extened to 1 high speed pulse output; 2 relay outputs; 2 analog output:volatge output 0~10VDC or current output 0~20mA | |
Human machine interface | LED Display | Can display setting frequency,output frequency,output voltage,output current,etc. |
Enviorment &Protection class | Protection class | IP20 |
Humidity&temperature | 90%RH or less(no-condensation),-10ºC~+40ºC.Inverter will be derated ifambien temperature exceeds 40ºC | |
Vibration | Under 20Hz9.8m/s(1G),Over 20Hz5.88m/s(0.6G) | |
Store environment | ≤1000M,indoor(no corrosive gas and liquid) | |
Store temperature | -20ºC~60ºC | |
Cooling Mode | Forced air-cooling |